Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13555874
| No.13555874
- Product Categories
- Friendly Links
- home > Supply > Electromagnetic pulse valve diaphragm, nine are brightly lit brand (certified), electromagnetic pulse valve
Electromagnetic pulse valve diaphragm, nine are brightly lit brand (certified), electromagnetic pulse valve
| Information Name: | Electromagnetic pulse valve diaphragm, nine are brightly lit brand (certified), electromagnetic pulse valve |
| Published: | 2015-03-02 |
| Validity: | 0 |
| Specifications: | Limited |
| Quantity: | |
| Price Description: | |
| Detailed Product Description: | FAQ pulse controller in dedusting equipment in use: DC24V output control device to ensure that the output voltage is it? DMF-T electromagnetic pulse valve, the output voltage when the pulse controller selection can meet the requirements of the electromagnetic pulse valve, pulse valve for cleaning effect has a greater impact, therefore, in the selection of the control valve coil electromagnetic pulse device, particularly DC24V when the control device, to determine whether controls have sent lusty enough voltage and current is very important, now two cases were analyzed: 1, relay output control device as a result of this type of controller output voltage through the relay contacts, there is no pressure drop, so long as the power of the rational part of the pulse controller design to achieve normal output is not a problem. 2, the use of high-power tube output due to the pulse controller at both ends of the resulting voltage pulse valve controller is the difference between the output voltage and the voltage drop of power, so the analysis controller circuit design parameters, determine whether the output side to get DC 24V stable is very important. How clever application control device control signal? 1, external pressure control switch with outside pressure control switch, you can take advantage of passive contact signal output as a differential pressure switch control signal, enabling control device automatically. 2. When using the panel mount as the system which uses an external start signal panel type switch for system start signal, the benefits far outweigh the direct control pulse controller power DMF-Y electromagnetic pulse valve, because Dian we all know, every single chip Power-times require 1-2 seconds settling time, and using this method, the MCU is in the transition state between standby and active. 3, do remote control signal is installed on top of the filter dust collector with many small dust when the control device are mounted directly on top of the filter, so that by the external control signals control instrument on and off is very convenient. Electromagnetic pulse valve diaphragm, nine are brightly lit brand (certified), electromagnetic pulse valve is provided by Botou brightly lit dust Equipment Co. Botou brightly lit dust Equipment Co., Ltd. (www.bttm.cn) Hebei Cangzhou, a leader in environmentally friendly products processing, over the years, the company is implementing the scientific management, innovation and development, the principle of honesty and trustworthiness, and satisfy customer needs. In the brightly lit dust leadership with the staff warmly welcome all inquiries negotiations to create a better future for brightly lit dust. |
Admin>>>
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

