Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13555874
| No.13555874
- Product Categories
- Friendly Links
| Information Name: | TM-201-D pulse controller, brightly lit dust, pulse controller |
| Published: | 2014-12-09 |
| Validity: | 0 |
| Specifications: | Limited |
| Quantity: | |
| Price Description: | |
| Detailed Product Description: | TM-201-D pulse controller, brightly lit dust, impulse control instrument provided by Botou brightly lit dust Equipment Co., Ltd. Botou brightly lit dust Equipment Co., Ltd. (www.bttmcc.com) is specialized in the "bag filters, electrostatic precipitators, bag filter accessories, electrostatic precipitator parts" of the enterprise, the company of "honesty, hard service "concept, to provide you with the highest quality products and services. Welcome to inquire! Contact: Wang Yan. Pulse controller crash phenomenon of reasons: First, consider the software issues, including the following reasons: 1, pulse controller programming into an infinite loop. This is the program design is the most common cause. 2, the data occurs in a program designed to overflow like now. 2, the pulse controller program does not overwrite the initial part of the time to enter, leading to the crash pulse controller. When you modify the first digital display to modify the parameters of the total number, which modify the order, display format and modify the meaning of the following one, "put pulse interval" - as the poppet valve output pulse valve between this unit of work the time interval in seconds. According to process requirements, mention pulse interval pulse controller set at any time based on site conditions, its value between 5-99 seconds. 2, "Pulse Width" - the duration of the output pulse of TM-SD-10 pulse controller, the adjustment range is 0.02 to 0.99 seconds. When setting TM-SD-30 pulse controller in 0.01 seconds, so the setting value from 0.02 to 0.99. 3, "Valve interval" - for a valve output pulse end to the valve adjacent to the start of the output pulse time interval, in seconds. According to process requirements, the pulse interval set at any time based on site conditions, its value between 3-999 seconds. 4, "the cycle interval" - time between two adjacent cleaning cycle interval in seconds. The adjustment range is 1 to 9990S. 5, "when cinder long" - cinder valve actuation time. The parameter adjustment range is 0-99S, 6, "cinder interval" - the number of cleaning cycles two adjacent unloading valve actuation time interval between the ash, which is the parameter adjustment range is 0-99 times. 7, "poppet numbers" - When this parameter is set to 0 for online cleaning state TM-A-20 pulse controller, when a non-zero when working offline, the adjustment range is 0-9. 8, "the group pulse valve number" - the number of valves per enhance impulse control valve. When you modify the display from the left 3-4 show the number of each group of ten pulse valve, a bit, the adjustment range is 1-18, set the parameters of outputs subject to restrictions, to be calculated after setting. 9, "display mode" - display mode. 0 for the economic model, one for normal mode. Concerned at the beginning of this chapter display mode has conducted a more detailed explanation. |
Admin>>>
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

