Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13555874

- Product Categories
- Friendly Links
- home > Supply > 2 Cunban submerged electromagnetic pulse valve, electromagnetic pulse valve, brightly lit dust
Information Name: | 2 Cunban submerged electromagnetic pulse valve, electromagnetic pulse valve, brightly lit dust |
Published: | 2014-11-17 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | Electromagnetic pulse valve power supply voltage according to the type of condition 1, were selected to AC and DC solenoid valve. Generally easy access to AC power. Two voltage specification with the best preferred AC220V.DC24V. 3 power supply voltage fluctuations are usually used +% 10% 15% .- DC allow ±% 10 or so, should ultra-poor 3-inch submerged electromagnetic pulse valve, regulators should take action or make a special order request. 4 should be selected according to the rated current and power consumption power capacity. VA should be noted that the value of the exchange starting higher, lack of capacity should be preferred indirect pilot solenoid valve. Troubleshooting of electromagnetic pulse valve after one or electromagnetic pulse valve power does not work Check power wiring is bad → re-wiring and connectors Check the power supply voltage is connected to the working range of ± - → tone caused by the normal range of positions the coil is re desoldering → Are welded coil shorted → replace the coil working pressure differential → → Adjust inappropriate or replace solenoid valve commensurate fluid temperature is too high → Replace commensurate with impurities so that the main valve spool solenoid valve and movable core stuck → conduct cleaning, replace the seal if the seal is damaged and install filter liquid viscosity is too large, the frequency is too high, and life expectancy has reached → replace the product two electromagnetic pulse valve can not close the main valve or moving iron core seal is damaged → Replace seals pieces of fluid temperature, viscosity is too high → Replace counterparts have impurities into the solenoid valve solenoid valve spool capacity for cleaning or moving core → spring has come to life or deformed → Replace the throttle Kong Pingheng clogging → timely cleaning frequency is too high or life has come to → reelection product or update product within three or otherwise leak → Check the seal is damaged a half inches at right angles to the electromagnetic pulse valve, spring is bad leak → junction assembly outside the seal has been broken or loose screws or replace → There is energized when the seal on the noise → chieftain fasteners loose, tighten. Voltage fluctuations are not within the allowable range, adjust the voltage. Core pull impurities or uneven surfaces, be cleaned or replaced. 2 Cunban submerged electromagnetic pulse valve, electromagnetic pulse valve, brightly lit by Botou brilliance dust removal equipment Limited. Botou brilliance dust Equipment Co., Ltd. (www.tmccsb.com) strong, credible, environmentally friendly products in Hebei Cangzhou processing industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving transparency innovative ideas will lead dust into the brilliant and you work for a better future! |
Admin>>>
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 42343 visitor
Copyright © GuangDong ICP No. 10089450, Botou brightly lit dust Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility